Products compared

INKBIRD
INKBIRD Temperature and Humidity Controller ITC-608T
The U.S. ITC-608T configuration compared here has one temperature probe and one humidity probe; INKBIRD’s product page also shows a separate two-temperature-probe configuration. In combined mode, the documented outputs cover temperature and humidity equipment; humidity-only mode uses both outputs for humidifying and dehumidifying.
Model ITC-608T (U.S. plug, 1 temperature probe + 1 humidity probe option)
Amazon ASIN B07GQWY9HM

Auber Instruments
Auber Instruments Dual Output Programmable Humidity Controller HD330
The base HD330 compared here is non-Wi-Fi; AW-HD330 is the separate Wi-Fi model. Auber specifies one humidity sensor, separate humidifier and dehumidifier outputs, a default 6 ft sensor cable, and up to eight humidity-time program steps.
Model HD330 base model (non-Wi-Fi, default 6 ft sensor cable)
Amazon ASIN B0727YQLPR
Differences that matter
What matters most to you?
Choose a priority to see what it changes.
Sources for What the two outputs control
Sources for How humidity targets change
Sources for Probe kit and sensor reach
Sources for Published electrical limits
Start with the devices you need to control
The INKBIRD ITC-608T is the mixed-role option in this pair. With its one-temperature/one-humidity U.S. probe kit, the manufacturer describes a combined mode that splits one output to temperature control and one to humidity control. The manual also documents a humidity-only mode for humidifying and dehumidifying roles.
The base Auber HD330 is different: it has one humidity sensor and one output for a humidifier plus another for a dehumidifier. It is not a temperature controller. If you need temperature equipment managed by the same controller, compare INKBIRD's combined mode; if temperature is already managed elsewhere, the Auber can focus both outputs on humidity.
Separate humidity scheduling from temperature scheduling
Auber specifies a single-step mode and a multi-step program with up to eight humidity-time stages. That addresses a buyer who needs humidity targets to change as time passes while temperature is handled by another system.
INKBIRD's product page advertises a 12-stage program for temperature settings. Its V5.0 manual describes humidity settings in the relevant modes; the evidence reviewed does not establish an equivalent timed humidity schedule. If a timed humidity sequence is the deciding requirement, the documented workflow points to Auber.
Check probe placement and the exact configuration
The U.S. ITC-608T option described on the product page has one temperature probe and one humidity probe and lists 2 m sensor cables. The page also shows a separate two-temperature-probe configuration, so check which configuration the offer includes.
The base Auber HD330 has one humidity sensor with a default 6 ft cable; Auber lists a longer 20 ft option separately. Measure the run to the measurement point and confirm which cable selection is included with the exact item you plan to order.
Treat ratings as limits, not an equipment approval
INKBIRD's U.S. product page lists 120 V AC, 15 A and 1800 W. Auber lists up to 15 A at each HD330 output but says total power across both is limited to 1500 W. The per-output ratings therefore cannot be summed into a 30 A combined allowance.
Those numbers alone do not establish a compatible load, starting demand or approved application. Check the controller and connected equipment's own current instructions and labels. This guide does not offer wiring, load modification, or hazardous-use advice.
Product details
INKBIRD Temperature and Humidity Controller ITC-608T
The ITC-608T is the option to examine when one controller needs temperature and humidity output roles together. Its 12-stage program described on the product page is for temperature settings; do not interpret that feature as timed humidity programming.
- Selected U.S. probe configuration
- One temperature probe and one humidity probe; alternate two-temperature-probe configuration is a separate selection Source
- Output-role options
- Combined mode assigns one output to temperature heating/cooling and one to humidity; humidity-only mode assigns the outputs to humidifying and dehumidifying Source
- Published U.S. electrical limits
- 120 V AC, 15 A, 1800 W total; rating does not establish compatibility with a particular connected device Source
Auber Instruments Dual Output Programmable Humidity Controller HD330
The HD330 is the option to examine when temperature is controlled separately and the humidity target itself needs a timed sequence. Its two output ratings must not be added together: Auber states a lower combined power limit.
- Humidity output roles
- One output for a humidifier and one for a dehumidifier; one humidity sensor Source
- Humidity scheduling
- Single-step control or up to eight humidity-time stages, up to 33.3 days total per maker specifications Source
- Combined output limit and default sensor cable
- Each output is rated up to 15 A; combined power is limited to 1500 W. Default sensor cable is 6 ft; a 20 ft option is listed separately. Source
Before you buy
Common questions
Does dual output mean the Auber HD330 can control temperature too?
No. Auber's base HD330 product page describes one humidity sensor and two outputs for humidifier and dehumidifier roles. The INKBIRD ITC-608T has a documented combined mode that can assign one output to temperature and the other to humidity.Dual Output Programmable Humidity Controller HD330INKBIRD ITC-608T English Product Manual, V5.0
Which controller supports a timed humidity program?
Auber specifies up to eight humidity-time stages for the HD330. INKBIRD's 12-stage program on its product page is described for temperature settings; do not treat that as a timed humidity program.Dual Output Programmable Humidity Controller HD330INKBIRD Temperature and Humidity Controller ITC-608T
Can the Auber's two 15 A outlet ratings be added together?
No. Auber states a 1500 W combined limit across its two outputs because of the input cord restriction, even though each output is listed up to 15 A. This does not determine whether a particular connected device is appropriate.Dual Output Programmable Humidity Controller HD330
Are the two products' probes the same length or configuration?
No. The U.S. ITC-608T option described here has one temperature probe and one humidity probe, and its product page lists a 2 m sensor cable. The base HD330 has one humidity sensor and defaults to a 6 ft cable; Auber lists a separate 20 ft option. Check the probe and cable configuration on the exact offer before ordering.INKBIRD Temperature and Humidity Controller ITC-608TDual Output Programmable Humidity Controller HD330
Sources and scope
This comparison covers the U.S. INKBIRD ITC-608T kit with one temperature probe and one humidity probe, and the base Auber HD330 with its standard 6 ft cable. Before ordering, check the included sensor and cable on the exact listing and compare your equipment’s ratings with the manufacturer’s limits.