Products compared

APC
APC Back-UPS BE600M1
U.S. black, 600 VA / 330 W Back-UPS with five battery-backup outlets and two surge-only outlets.
Model BE600M1
Amazon ASIN B01FWAZEIU

APC
APC Back-UPS Pro BX1500M
U.S. black tower, 1,500 VA / 900 W Back-UPS Pro with AVR/LCD, five battery-backup outlets and five surge-only outlets.
Model BX1500M
Amazon ASIN B06VY6FXMM
Differences that matter
What matters most to you?
Choose a priority to see what it changes.
Sources for Battery-backed versus surge-only outlets
Sources for Replacement battery and maintenance identity
Sources for Waveform while running on battery
First size the devices that need backup
Start with the gear you need to keep on during an outage, not every device you might plug into the strip. Write down each device's VA and watt requirement from its label or manual, then compare the combined requirements with the UPS. Schneider Electric lists BE600M1 at 600 VA/330 W and BX1500M at 1,500 VA/900 W. Its support guidance says to check the watt rating and identify which equipment actually needs battery backup.
If the planned load is within BE600M1's published limits, that model may meet the stated capacity requirement. If it exceeds either BE600M1 limit but remains within both BX1500M limits, the larger rating may fit the plan. If it exceeds BX1500M's 1,500 VA or 900 W limit, neither published rating covers it. These thresholds do not tell you runtime; this guide does not estimate minutes for your configuration.
Separate backed outlets from surge-only connections
Both models list five outlets for battery backup and surge protection. Their extra outlets differ: BE600M1 has two surge-only sockets, while BX1500M has five. Schneider Electric's guidance is to put equipment that must remain on during an outage into the battery-backed sockets and connect noncritical equipment to surge-only outlets.
Make a physical outlet map before buying: label each planned device 'must stay on' or 'surge only,' count those groups, and check the equipment plugs against the layout in the product listing. A free surge-only socket cannot substitute for a battery-backed one, and more sockets do not increase the UPS's VA/W rating.
Plan replacement around the exact UPS model code
Both product families have a user-replaceable battery, but not the same cartridge. Schneider Electric's model table pairs BE600M1 with APCRBC154 and BX1500M with APCRBC124. Its BX1500M manual also lists a 24 V lead-acid assembly and APCRBC124, while the APCRBC154 listing describes a 12 V, 6.5 Ah lead-acid cartridge for Back-UPS.
Keep the unit's model number in your maintenance records and match it before ordering a spare. This comparison does not rank battery life or replacement cost; it simply makes the part-number distinction visible before the original battery reaches the replacement indicator.
Waveform is shared; check equipment requirements separately
The BE600M1 data sheet says 'stepped approximation to a sinewave'; the BX1500M manual calls its on-battery waveshape 'step-approximated sine-wave.' That is the same broad type for this pair, so it does not separate the two choices. Neither cited model source describes the output as pure sine wave.
If a computer, audio device, or other connected product specifies a particular UPS waveform requirement, check that product's manufacturer documentation and the exact UPS model specification. Do not infer compatibility or operating behavior from the VA/W rating or from this comparison.
Product details
APC Back-UPS BE600M1
Schneider Electric's U.S. data sheet identifies BE600M1 and lists 600 VA/330 W, five battery-backed receptacles plus two surge-only receptacles, and its on-battery waveform. Schneider identifies APCRBC154 as the user-replaceable part for this exact model.
- Rated capacity
- 600 VA / 330 W Source
- Outlet allocation
- 7 total: 5 battery-backup and surge-protected; 2 surge-only Source
- On-battery waveform
- Stepped approximation to a sine wave Source
- Replacement battery
- User-replaceable APC APCRBC154 cartridge; 12 V, 6.5 Ah lead-acid replacement cartridge Source
- USB charging
- One USB Type-A smart-charging port is listed Source
APC Back-UPS Pro BX1500M
The U.S. product page identifies BX1500M and lists 1,500 VA/900 W. Its exact marketplace listing and model-family manual identify five backup plus five surge-only outlets; the manual lists the matching APCRBC124 replacement and step-approximated on-battery sine waveform.
- Rated capacity
- 1,500 VA / 900 W Source
- Outlet allocation
- 10 total: 5 battery-backup and 5 surge-only Source
- On-battery waveform
- Step-approximated sine wave Source
- Replacement battery
- User-replaceable APC APCRBC124 cartridge; BX1500M documentation lists a 24 V lead-acid battery assembly Source
- USB charging
- Schneider Electric's U.S. marketplace specifications list no USB power supply; the manual's USB port is for data/PowerChute connection Source
Before you buy
Community discussions
A router-and-NAS buyer asks whether a small UPS fits
APC Back-UPS BE600M1
The poster is looking for a UPS for a router and Synology DS220+ and asks whether the APC BE600M1 is suitable. The post gives intended equipment, not a measured load or a recommendation.
What to check
List the devices that need battery-backed outlets, then compare that outlet layout and their labeled load with the exact APC and BX1500M model data. The thread does not settle which size is right.
Common questions
How much more load does the BX1500M support on paper?
Schneider Electric lists 600 VA/330 W for BE600M1 and 1,500 VA/900 W for BX1500M. Compare the combined VA and watts for the devices you plan to keep on battery with the exact UPS ratings. The difference does not predict backup runtime.BE600M1 U.S. product data sheetBX1500M - APC Back-UPS Pro U.S. product pageEquipment connected to a Back-UPS product turns off unexpectedly and/or reboots
Do both models have battery-backed outlets?
Yes. Each lists five battery-backed outlets. BE600M1 adds two surge-only outlets; BX1500M adds five surge-only outlets. Put outage-critical equipment on the outlets marked Battery Backup and use surge-only outlets for devices that do not need backup, following Schneider Electric's guidance.APC Back-UPS BE600M1 U.S. product listing and specificationsAPC Back-UPS Pro BX1500M U.S. product listing and specificationsEquipment connected to a Back-UPS product turns off unexpectedly and/or reboots
Are the replacement batteries the same?
No. Schneider Electric identifies APCRBC154 as the user-replaceable battery for BE600M1 and APCRBC124 for BX1500M. Confirm the exact UPS model before ordering a replacement cartridge.Schneider Electric USA/Canada Back-UPS replacement battery model table
Does BX1500M provide a pure sine wave on battery?
The cited BX1500M manual says step-approximated sine wave; the BE600M1 data sheet uses stepped approximation to a sine wave. The documents reviewed do not describe either selected model as pure sine. Check the connected equipment maker's requirements instead of inferring compatibility.APC Back-UPS Pro BX850/1000/1350/1500M user manualBE600M1 U.S. product data sheet
Sources and scope
This guide compares manufacturer-listed U.S. model specifications and load-assignment guidance. It does not report a load test, runtime test, or electrical-performance result. VA and W ratings are capacity limits, not backup-time predictions. Actual equipment requirements and plug layout must be checked from the connected equipment labels and manuals. Both selected models are documented with a stepped approximation to a sine wave while on battery; equipment-specific waveform compatibility is not assumed. Use only the specified replacement cartridge for the exact UPS model.
- BE600M1 - APC Back-UPS 600VA U.S. product page
- BE600M1 U.S. product data sheet
- APC Back-UPS BE600M1 U.S. product listing and specifications
- BX1500M - APC Back-UPS Pro U.S. product page
- APC Back-UPS Pro BX1500M U.S. product listing and specifications
- APC Back-UPS Pro BX850/1000/1350/1500M user manual
- Schneider Electric USA/Canada Back-UPS replacement battery model table
- Equipment connected to a Back-UPS product turns off unexpectedly and/or reboots