Products compared

CyberPower
CyberPower EC850LCD Ecologic UPS
US 120 V EC850LCD model; 850 VA / 510 W; battery and surge, surge-only and ECO-controlled outlet groups.
Model EC850LCD
Amazon ASIN B00DBAA696

APC
APC Back-UPS Pro BX1500M
US 120 V BX1500M tower model; 1500 VA / 900 W; five battery-backed and five surge-only NEMA 5-15R outlets.
Model BX1500M
Amazon ASIN B06VY6FXMM
Differences that matter
What matters most to you?
Choose a priority to see what it changes.
Sources for Rated output ceiling
Sources for Battery-backed vs surge-only outlets
Sources for Battery service and replacement
Sources for Published runtime evidence at each model's rated load
Sources for Load-planning workflow
Start with the equipment load, not the VA headline
The EC850LCD is rated 850 VA / 510 W; the BX1500M is rated 1500 VA / 900 W. Check both apparent power and watts for the equipment you plan to connect: meeting one limit does not establish that the other is met. CyberPower's EC850LCD manual recommends keeping that model's load below 80% of its rating; that recommendation is model-specific and is not stated here as an APC rule.
Before purchase, make a device list from manufacturer labels/specifications, total known VA and watts separately, then compare the totals with the selected UPS's limits. If your device specifications or startup requirements are unclear, check the equipment and UPS makers' guidance rather than inferring compatibility from a product category.
Map the battery-backed outlets before plugging in
EC850LCD documents 12 total outlets: six battery-and-surge protected, six surge-only, with three of the surge-only outlets ECO-controlled. BX1500M documents 10 total: five battery-backup-and-surge and five surge-only. Count only the devices you expect to need on battery, then confirm the plug shape and spacing in the product manual; the total outlet count alone does not guarantee that bulky adapters will fit together.
The EC850LCD manual gives specific guidance on which kinds of peripherals belong on its backed versus surge-only outlets. Follow the exact unit manual and connected equipment instructions; this guide does not certify any load as safe or compatible.
Compare the battery replacement path
CyberPower's EC850LCD specification lists RB1270B, says the battery is not user-replaceable and identifies field service by a qualified technician. Schneider's replacement table lists BX1500M with a user-replaceable APCRBC124 cartridge. If serviceability is part of your purchase decision, check the current manufacturer support route and exact replacement part for the regional unit you are buying; do not assume two lead-acid UPS batteries use interchangeable cartridges.
Read runtime figures with their load conditions
ENERGY STAR's exact-model record lists EC850LCD runtime of 1 minute at 100% of its 510 W rating and 6 minutes at 50% (255 W). The BX1500M record lists 3 minutes at 100% of 900 W and 11 minutes at 50% (450 W). Those are percentages of different rated loads, not a matched 255 W or 450 W comparison. CyberPower's product specification page separately lists 2.3 minutes at full load and 7.9 minutes at half load, so the EC850LCD documents disagree.
Because of the different load points and CyberPower value discrepancy, do not treat those entries as a typical runtime comparison or estimate how long your computer will run. The EC850LCD manual describes its LCD runtime estimate as dependent on current load and battery capacity.
Product details
CyberPower EC850LCD Ecologic UPS
Before you buy
Community discussions
Checking outlet space for bulky adapters
APC Back-UPS Pro BX1500M
In a discussion about the APC BX1500M, a commenter raised the possibility of wide adapters covering neighboring outlets.
What to check
Compare the shapes of your plugs with the outlet layout and count how many you can use at the same time.
Common questions
Is the APC BX1500M automatically the right choice because it is 1500 VA?
Not automatically. It has a higher published ceiling at 1500 VA / 900 W, but check your load in both VA and watts and confirm the five battery-backed outlets fit your equipment. If your load fits within 850 VA / 510 W and the EC850LCD's six backed outlets fit, the smaller rating may cover the documented requirement.ENERGY STAR Certified UPS: CyberPower EC850LCDENERGY STAR Certified UPS: APC Back UPS Pro BX1500M
Which UPS lets the owner replace its battery?
Schneider lists a user-replaceable APCRBC124 battery for BX1500M. CyberPower lists EC850LCD as not user-replaceable, with RB1270B service by a qualified technician. Verify the exact cartridge and support conditions for your region before ordering parts.BX1500M replacement battery table | Schneider ElectricEC850LCD Ecologic UPS product details and specifications
Can I use the listed minutes as my computer's backup runtime?
No. The published ENERGY STAR figures are measured at percentages of each UPS's own rated load, which means different watt loads here. CyberPower's product page also lists different EC850LCD values from its ENERGY STAR record. Use the exact unit's current LCD estimate after checking your actual load; this guide does not calculate a runtime for your setup.ENERGY STAR Certified UPS: CyberPower EC850LCDEC850LCD Ecologic UPS product details and specificationsENERGY STAR Certified UPS: APC Back UPS Pro BX1500MCyberPower Ecologic UPS Series EC850LCD User Manual
Sources and scope
Match runtime information to the actual load. CyberPower and ENERGY STAR give different EC850LCD runtime values. Confirm the power draw and outlet requirements of the equipment you plan to connect.
- EC850LCD Ecologic UPS product details and specifications
- CyberPower Ecologic UPS Series EC850LCD User Manual
- ENERGY STAR Certified UPS: CyberPower EC850LCD
- APC Back-UPS Pro BX1500M product page | Schneider Electric USA
- BX1500M replacement battery table | Schneider Electric
- ENERGY STAR Certified UPS: APC Back UPS Pro BX1500M