Products compared

CyberPower
CyberPower PFC Sinewave UPS 1500VA/1000W
The assigned U.S. listing data product is CyberPower model CP1500PFCLCDA. CyberPower's exact SKU page styles the model CP1500PFCLCDa and prints CP1500PFCLCDA in its included-product line. It lists 1500VA/1000W, pure sine-wave output, 12 NEMA 5-15R outlets split six battery-and-surge plus six surge-only, and USB-A/USB-C charging. Match the final model characters on the specific offer; do not assume that a listing for base CP1500PFCLCD is identical.
Model CP1500PFCLCDA
Amazon ASIN B00429N19W

APC
APC Back-UPS Pro BX1500M 1500VA/900W
The assigned U.S. listing data product is APC Back-UPS Pro BX1500M. Schneider Electric's U.S. listing identifies SKU BX1500M, rates it at 1500VA/900W, and specifies a stepped approximation to a sine wave. It lists 10 NEMA 5-15R outlets split five battery backup and five surge-only, with replaceable battery APCRBC124. The manual explicitly covers BX1500M; confirm the exact suffix on the offer.
Model BX1500M
Amazon ASIN B06VY6FXMM
Differences that matter
What matters most to you?
Choose a priority to see what it changes.
Sources for Watt ceiling versus shared VA rating
Sources for On-battery waveform documentation
Sources for Device charging ports and replacement-part lookup
Start with watts, not the shared 1500VA figure
Both are labeled 1500VA, but CyberPower publishes a 1000W limit and APC BX1500M publishes 900W. Write down the combined watt draw of the equipment you actually intend to back up, using its maker documentation or a suitable meter, and compare that load with the rated limit. Keep margin for the way the equipment operates; this is a planning check, not a promise that a setup will run for a particular duration.
The output waveform is another fit check. CyberPower specifies pure sine-wave on-battery output and lists active-PFC compatibility. APC specifies a stepped approximation to a sine wave. Check the connected device's own documentation for any UPS waveform requirement. The specifications do not prove how a specific computer, NAS, router, or power supply behaves with either UPS.
Count essential plugs in the battery-backed bank
CyberPower lists 12 NEMA AC outlets split six battery-and-surge protected and six surge-only. APC BX1500M lists 10 outlets split five battery-backup and five surge-only. During a power outage, the surge-only group does not provide battery backup; Schneider Electric's support guidance states that distinction for BX1500M.
Before checkout, make a short load map: computer, display, router or modem, and any other equipment that truly needs temporary battery power. Compare that list with the six or five backed outlets, then check the exact rear-panel layout for plug clearance. Do not count USB charging ports as AC outlets or as additional battery-backed sockets.
Compare charging and future battery lookup separately
CyberPower lists one USB-A and one USB-C charging port, with total USB output stated as 5V / 3.1A. APC's BX1500M U.S. listing says there is no USB power supply. If USB charging is convenient for a small accessory, treat it as a separate feature from the AC backup outlet count and check its charging requirements.
For a later replacement, CyberPower identifies RB1290X2 for this exact SKU and APC's BX1500M manual lists APCRBC124. Keep the model and cartridge numbers together in your records and verify both labels if replacement is needed. This comparison does not estimate battery life, service cost, or how long a loaded UPS will operate.
Product details
CyberPower PFC Sinewave UPS 1500VA/1000W
- Rated capacity and output
- 1500VA / 1000W; 120V input; pure sine-wave output on battery. The published ratings do not establish runtime or compatibility with a particular connected device. Source
- AC outlet allocation
- 12 NEMA 5-15R outlets: 6 battery-and-surge protected and 6 surge-only. Count only the battery-backed group for devices that must receive UPS battery power during an outage. Source
- USB charging and battery replacement part
- The exact SKU page lists one USB-A and one USB-C charging port, with total USB charging output listed as 5V/3.1A, plus user-replaceable battery pack RB1290X2. These USB charging ports are separate from the AC outlet count. Source
APC Back-UPS Pro BX1500M 1500VA/900W
- Rated capacity and output
- 1500VA / 900W; 120V input/output; stepped approximation to a sine wave on battery. These specifications do not establish runtime or compatibility with a particular connected device. Source
- AC outlet allocation
- 10 total outlets: 5 battery-backup plus surge-protection outlets and 5 surge-only outlets. The BX1500M manual explains that surge-only outlets do not provide battery backup during an outage. Source
- Replacement battery part
- The BX1500M manual lists replacement battery APCRBC124; Schneider Electric's product listing also identifies APCRBC124 as the compatible replacement cartridge. Verify the UPS and battery part labels before ordering replacement parts. Source
Before you buy
Community discussions
Checking where a tower UPS fits under a desk
CyberPower PFC Sinewave UPS 1500VA/1000W
A CP1500PFCLCDa owner wanted their UPS off the desktop and found their existing under-desk holder had too little height.
What to check
Measure the space beside your desk and check where each unit’s rear outlets will face.
Common questions
Are 1500VA and 1500VA the same usable load capacity?
Not by themselves. CyberPower lists 1500VA / 1000W and APC BX1500M lists 1500VA / 900W. Compare the measured watts for the equipment you intend to back up against the model's watt limit; those figures do not predict runtime.CyberPower CP1500PFCLCDa exact-model specifications and replacement battery referenceSchneider Electric U.S. APC BX1500M product specifications
How many devices can receive battery backup?
The outlet counts are six battery-and-surge outlets for CyberPower and five battery-backup outlets for APC BX1500M. Each unit has additional surge-only outlets; those should not be counted as battery-backed plugs. Count the essential devices and confirm plug spacing on the exact unit before ordering.CyberPower CP1500PFCLCDa exact-model specifications and replacement battery referenceSchneider Electric U.S. APC BX1500M product specificationsSchneider Electric U.S. Back-UPS Pro BX1500M outlet and battery support FAQ
Does the output waveform tell me which unit my computer will work with?
It tells you what each manufacturer documents, not the outcome for your exact computer. CyberPower specifies pure sine-wave output and lists active-PFC compatibility; APC BX1500M specifies a stepped approximation to a sine wave. Check the connected equipment maker's UPS requirements and do not treat either statement as universal compatibility.CyberPower CP1500PFCLCDa exact-model specifications and replacement battery referenceSchneider Electric U.S. APC BX1500M product specifications
Can I estimate battery runtime from the watt or VA rating?
No. Runtime depends on actual load and operating conditions. Use the exact manufacturer's runtime chart or calculator with your measured load and required shutdown window; this comparison does not rank runtime or estimate a particular setup.CyberPower CP1500PFCLCDa exact-model specifications and replacement battery referenceSchneider Electric U.S. APC BX1500M product specificationsAPC Back-UPS Pro BX850/1000/1350/1500M user manual
Which replacement battery part numbers are listed?
CyberPower's exact CP1500PFCLCDa page lists replacement pack RB1290X2. Schneider Electric's BX1500M documentation lists APCRBC124. Check the UPS model label and the replacement cartridge label before ordering; this comparison does not claim either part fits the other model.CyberPower CP1500PFCLCDa exact-model specifications and replacement battery referenceAPC Back-UPS Pro BX850/1000/1350/1500M user manualAPC APCRBC124 replacement cartridge product page
Sources and scope
This guide compares exact-model manufacturer and official support specifications; it is not a load, runtime, compatibility, safety or reliability test. Both list 1500VA, but their watt ratings differ. CyberPower's official SKU page calls the model CP1500PFCLCDa and its included-product line prints CP1500PFCLCDA; the current the listed model also carries the uppercase A, so check the exact offer label and do not substitute the similarly named CP1500PFCLCD. The APC manual covers a model family and explicitly includes BX1500M. Runtime depends on connected load and conditions; use the applicable manufacturer's runtime guidance rather than these capacity labels. No current price or inventory promise is included.
- CyberPower CP1500PFCLCDa exact-model specifications and replacement battery reference
- CyberPower RB1290X2 replacement battery pack
- Schneider Electric U.S. APC BX1500M product specifications
- APC Back-UPS Pro BX850/1000/1350/1500M user manual
- Schneider Electric U.S. Back-UPS Pro BX1500M outlet and battery support FAQ
- APC APCRBC124 replacement cartridge product page